UI reference

Review Pseudonym Profile

Preset rule sets: Basic, +Pixel, HIPAA, Teaching, or Custom.

Each profile is a set of tag rules. All of them start from the DICOM PS3.15 Basic profile.

  • Basic is the PS3.15 Basic Application Level Confidentiality Profile. Every attribute in the standard’s Table E.1-1 (2026c edition) gets the action the table gives it: remove, blank, dummy value or new UID. Where the table offers a choice, such as “remove or blank”, dcmage keeps the attribute and blanks it or gives it a dummy value, which is valid for any image type. Patient’s Name and Patient ID get the pseudonym.
  • +Pixel is Basic plus removal of the whole overlay range, groups 6000 to 60FF. Basic itself removes only the overlay data and overlay comments.
  • HIPAA is Basic plus the Safe Harbor list. Where both name a tag, the stricter action wins, so Patient’s Age is removed unless dates are shifted.
  • Teaching is HIPAA, but Study Description, Series Description and Protocol Name are kept word for word.
  • Custom starts from +Pixel (Basic plus the whole overlay range), and your rule overrides apply on top.

What the exported file records

Every profile sets Patient Identity Removed (0012,0062) to YES and writes De-identification Method (0012,0063) as text, for example “dcmage Basic profile, dates shifted”.

Basic, +Pixel and HIPAA also write the standard profile code 113100 in De-identification Method Code Sequence (0012,0064), with the private-tag scrub on Remove all and no custom rules. A date option adds its own code: shifting adds 113107 and 113108, keeping the original dates adds 113106. Teaching and Custom never write a code, and neither does a run that keeps private tags, because neither result is the standard profile.