Validation

Conformance check against storage tables

Validate a file against the DICOM storage conformance tables and report deviations.

Problem

DICOM files must conform to the IOD (Information Object Definition) requirements for their SOP Class. Non-conformant files may fail to load in PACS or cause downstream processing errors. You need to validate a file against the DICOM standard storage tables.

Steps

  1. Open the DICOM file. Click Files on the start screen (⌘O).
  2. Open the QA panel. Click the QA tab in the right rail.
  3. Review conformance results. The QA panel displays three categories: Errors (red) for mandatory Type 1 tags missing or empty, Warnings (yellow) for Type 2 tags missing, and Conditional (blue) for Type 1C/2C tags whose presence depends on other tag values.
  4. Drill into failures. Click an error row to navigate to the offending tag in the metadata tree.
  5. Fix and re-validate. Edit the tag in Edit mode (Ctrl+2 / ⌘2 in the desktop app). The QA panel live-updates as you correct each issue.
  6. Verify. Once all errors are resolved, the errors count shows “0 errors”.

Result

The QA panel in the right rail shows error, warning, and conditional counts in distinct colors; clicking an error jumps to the offending tag, and editing a flagged tag updates the panel live.