Specialized modalities

RTDOSE scale

Edit the Dose Grid Scaling (3004,000E) tag of an RT Dose object. Dose values are not recalculated.

Problem

An RT Dose (RTDOSE) object has a Dose Grid Scaling factor (3004,000E) that needs adjustment: the original value was exported incorrectly or needs to be modified for a dose recalculation downstream. You need to edit this tag in the tag editor. dcmage does not recalculate the dose.

Steps

  1. Open the RTDOSE DICOM file (⌘O), e.g. rtdose.dcm.

  2. Switch to Edit mode (Ctrl+2 / ⌘2 in the desktop app) and filter for (3004,000E) (Dose Grid Scaling).

  3. Edit the value. Double-click, enter a valid DS (Decimal String) value like 2.5, and save.

  4. Verify. The row is marked as modified (gold highlight) and the new value is displayed.

Validation

  1. Attempt an invalid value. Try entering not-a-number into the Dose Grid Scaling field. The save button is disabled and a red VR validation error is shown (DS VR requires a numeric string). Cancel to dismiss.

Result

Valid numeric values (e.g. 2.5) save, while non-numeric input is rejected and canceling leaves the row unmodified. This is a metadata-only edit: the dose pixel data is not recalculated.